ERROR CODES
®
C
OMBITHERM
ELECTRIC COMBITHERM INSTALLATION MANUAL #MN-28677
PG. 29
I
n the event of an error code, the Combitherm may be operated on a limited basis. Error conditions under
which continued operation can be conducted are indicated by “Yes” in the chart shown below.
W
hen the oven malfunctions, an error code will appear in the display.
PRESS THE START KEY TO ACKNOWLEDGE THE ERROR.
The keys that begin to flash represent operational modes that are still usable.
SELECT AND PRESS ONE OF THE COOKING MODES INDICATED.
The oven control will only respond to the mode keys that are flashing.
SET THE OVEN CONTROLS AS IF OPERATING UNDER NORMAL CIRCUMSTANCES.
Depending on the error code involved, oven function, such as temperature range, may be limited.
PRESS THE START KEY TO BEGIN THE COOKING PROCESS.
PRESS THE START KEY WHEN THE TIMER EXPIRES.
When the oven fault is corrected, the Combitherm will return to normal Operation.
CONTINUED OPERATION UNDER ERROR CONDITIONS
E M E R G E N C Y O P E R A T I O N
Error
Code
Display Shows ES ESi Steam
Mode
Combination
Mode
Convection
Mode
Retherm
Mode
E01 Low Water Yes No No No To 365°F No
E02 Control Temp High Yes Yes Yes To 284°F To 284°F To 284°F
E03 Fan Malfunction No No
E04 Aux Fan Fault Yes Yes Yes To 284°F To 284°F To 284°F
E11 Excess Oven Temp Yes Yes No No No No
E13 Excess Steam Gen Temp Yes No No No No No
E15 Excess Condensate Temp Yes Yes No No To 356°F No
E21 Oven Probe Fault Yes Yes 212°F only No No No
E22 Core Temp Probe Fault Yes Yes Yes Yes Yes Yes
E23 Steam Gen Probe Fault Yes No Yes Yes Yes Yes
E24 Bypass Probe Fault Yes Yes To 210°F No Yes No
E25 Condensate Probe Fault Yes Yes Yes To 356°F To 356°F To 320°F
E26 Steam Gen Safety Probe Fault Yes No Yes Yes Yes Yes
E27 Excess Steam Gen Safety Temp Yes No No No No No
E29 Probe Short to Frame Yes Yes No No No No
E34 DE (Drain) Pump Failure Yes No Yes Yes Yes Yes
E35 Venting Error Yes Yes Yes Yes Yes Yes
E36 Steam Temp High No Yes No No Yes No
E80 ID Error Yes Yes Yes Yes Yes Yes
E81 Program Memory Error Yes Yes Yes Yes Yes Yes
E82 WP Error Yes Yes Yes Yes Yes Yes
E83 Algo Error Yes Yes Yes Yes Yes Yes
E96 Connection Error Yes Yes No No No No