ELECTRIC COMBITHERM INSTALLATION MANUAL #MN-28677
PG. 20
®
COMBITHERM
INSTALLATION REQUIREMENTS
MOBILE EQUIPMENT RESTRAINT
Any appliance that is not furnished with a power
supply cord but includes a set of casters must be
installed with a tether. Adequate means must be
provided to limit the movement of this appliance
without depending on or transmitting stress to the
electrical conduit. The following requirements apply:
1. Casters must be a maximum height of 6" (152mm).
2. Two of the casters must be the locking type.
3.
Such mobile appliances or appliances on mobile
stands must be installed with the use of a flexible
connector secured to the building structure.
A mounting connector for a restraining device is
located on the lower back flange of the appliance
chassis or on an oven stand, approximately
18" (457mm) from the floor. A flexible connector is
not supplied by nor is it available from the factory.
DRIP TRAY INSTALLATION
The appliance is shipped without the drip tray
installed. This must be installed before equipment
operation begins.
Position drip tray mounting bracket beneath oven.
Secure with lock washer and phillips screws supplied.
Slide drip tray assembly into mounting bracket.
Secure with lock washer and nut.
Attach drip tray hose to drip tray assembly. Secure the
drain fitting connection with the 19mm clamp. Pull hose
tight, cut hose to length, and secure the drip tray hose
connection with the 20mm clamp.
ITEM
NO
.
PART
NO
.
PART DESCRIPTION QTY
1 1006674 DRIP TRAY MOUNTING BRACKET 1
2 DRIP TRAY 1
3 HO-27220 DRIP TRAY HOSE 1
W A R N I N G
FAILURE TO PROPERLY INSTALL THE
DRIP TRAY CAN OR WILL CAUSE
MAJOR EQUIPMENT DAMAGE AND
WILL RESULT IN A LEAKAGE
HAZARD THAT CAN CAUSE
PERSONAL INJURY.
W A R N I N G
RISK OF ELECTRIC SHOCK.
Appliance must be secured
to building structure.