0

Out of 0 Ratings

Owner's of the Alto-Shaam Microwave Oven 6.10 gave it a score of 0 out of 5. Here's how the scores stacked up:
  • Reliability

    0 out of 5
  • Durability

    0 out of 5
  • Maintenance

    0 out of 5
  • Performance

    0 out of 5
  • Ease of Use

    0 out of 5
of 36
 
ELECTRIC COMBITHERM INSTALLATION MANUAL #MN-28677
PG. 12
®
COMBITHERM
10•18ES SPECIFICATIONS
CA PAC ITY
FULL-SIZE PANS: 20" x 12" x 2-1/2" Twenty (20)
GN 1/1: 530 x 325 x 65mm Twenty (20)
GN 2/1: 650 x 530 x 65mm Ten (10)
FULL-SIZE SHEET PANS:* 18" x 26" x 1" Ten (10)
ON WIRE SHELVES ONLY
240 lb (109 kg) MAXIMUM
VOLUME MAXIMUM
: 150 QUARTS (190 LITERS)
WE IGH T
NET 522 lb (237 kg)
SHIP 646 lb (293 kg)
CRATE 46" X 51" X 46" EST.
DIMENSIONS: (1168 x 1295 x 1168mm)
EL ECT RIC AL
VOLTAGE PHASE CYCLE/HZ AWG AMPS kW
at 208 3 50/60 3 Wire plus ground 61.3/ph 22.0
at 240 AWG 2 70.0/ph 29.2
at 380 3 50/60 4 Wire plus ground 33.5/ph 22.0
at 415 AWG 6 40.7/ph 29.2
at 440 3* 50/60 3 Wire plus ground 36.0/ph 27.2
at 480 AWG 6 43.5/ph 36.1
* ELECTRICAL SERVICE CHARGE APPLIES
208-240
380-415
440-480
Decalcification
Port
30"
(760mm)
22-3/8"
(568mm)
15-1/2"
(393mm)
12-3/4"
(323mm)
E
lectrical Connection
(Bottom)
2" (50mm)
4
6-7/8" (1190mm)
43-7/8"
(
1114mm)
41-15/16"
(
1064mm)
4
0-1/8"
(
1019mm)
25-5/8"
(
650mm)
8
-11/16"
(219mm)
6-1/4" (158mm)
W
ater Drain
(
Bottom)
4
2-13/16"
(1087mm)
3
3-1/8"
(
840mm)
4
-15/16"
(
125mm)
S
team
V
ents
(Top)
W
ater Drain
(
Side Back)
69-3/8" (1761mm)
7-9/16" (192mm)
40-7/16" (1026mm)
32-7/8"
(834mm)
T
reated Water
I
ntake (Bottom)
Untreated Water
I
ntake (Bottom)
4
-11/16" (120mm)
2-5/16" (58mm)
DI MEN SIO NS: H x W x D
EXTERIOR:
40-7/16" x 43-7/8" x 42-13/16" (1026mm x 1114mm x 1087mm)
EXTERIOR WITH RETRACTABLE DOOR:
40-7/16" x 47-7/8" x 42-13/16" (1026mm x 1216mm x 1087mm)
INTERIOR:
30-3/4" x 23-1/2" x 28-7/16" (781mm x 596mm x 722mm)
*ADDITIONAL WIRE SHELVES REQUIRED FOR MAXIMUM CAPACITY
IN STA LLAT ION RE QUI RE MEN TS
Oven must be installed level.
Hood installation is required.
Water supply shut-off valve and back-flow
preventer.
CL EAR ANC E R EQU IRE MEN TS
LEFT: 6" (152mm) PLUS SERVICE ACCESS: 18" (457mm) RECOMMENDED
20" (508mm) FROM HEAT PRODUCING EQUIPMENT
RIGHT
: 4" (102mm) TOP: 20" (508mm) FOR AIR MOVEMENT
BACK
: 4" (102mm) BOTTOM: 5-1/8" (130mm) FOR LEGS
COUNTER
-TOP INSTALLATIONS MUST MAINTAIN 4" (102mm) MINIMUM
CLEARANCE FROM COUNTER SURFACE
.
WATE R R EQU IRE MEN TS
TWO (2) COLD WATER INLETS - DRINKING QUALITY
ONE (1) TREATED WATER INLET: 3/4" NPT*
ONE (1) UNTREATED WATER INLET: 3/4" NPT*
LINE PRESSURE: 30 to 90 psi 2.8 to 6.2 bar
WATER DRAIN: 1-1/2"
CONNECTION WITH AIR GAP
* Can manifold off of one 3/4" line.
WATE R Q UAL ITY MI NIM UM STA NDA RDS
USING A WATER SUPPLY NOT MEETING ALTO-SHAAM'S
MINIMUM WATER QUALITY STANDARDS WILL VOID THIS
WARRANTY. It is the responsibility of the purchaser to ensure that
incoming water supply is compliant with the specifications listed
through adequate treatment measures. Installation of the
CombiGuard™ Water Filtration System is recommended, but this
system may not address all water quality issues present.
Contaminant Inlet Water Requirements
(untreated water)
Free Chlorine Less than 0.1 ppm (mg/L)
Hardness Less than 3 gpg (52 ppm)
Chloride Less than 30 ppm (mg/L)
pH 7.0 to 8.5
Alkalinity Less than 50 ppm (mg/L)
Silica Less than 12 ppm (mg/L)
Total Dissolved
Solids (tds) Less than 60 ppm