ELECTRIC COMBITHERM INSTALLATION MANUAL #MN-28677
PG. 8
®
COMBITHERM
10•10ESi SPECIFICATIONS
33-1/16" (840mm) 4-15/16"
(125mm)
41-1/2" (1053mm)
33-15/16" (861mm)
7-9/16" (192mm)
60-9/16" (1538mm)
Water Drain
(Back Side)
30" (761mm)
4-3/4" (120mm)
2-3/16" (56mm)
11-7/16"
(290mm)
14-3/16"
(360mm)
15-7/8"
(403mm)
Electrical Connection (Bottom)
2" (50mm)
46-7/8" (1190mm)
4
3-7/8" (1114mm)
3
1-3/8" (796mm)
34-1/16" (865mm)
17-15/16"
(
456mm)
7-9/16"
(
191mm)
Water Drain
6-1/4" (158mm)
4
1-15/16" (1064mm)
T
reated Water
Intake (Bottom)
U
ntreated Water
Intake (Bottom)
Steam Vent (Top)
Low Pressure
Valve (Top)
CA PAC ITY
FULL-SIZE PANS: 20" x 12" x 2-1/2" Ten (10) Eight (8)
GN 1/1: 530 x 325 x 65mm Ten (10) Eight (8)
HALF-SIZE SHEET PANS:* 18" x 13" x 1" Ten (10) Nine (9)
ON WIRE SHELVES ONLY
120 lb (54 kg) MAXIMUM
VOLUME MAXIMUM
: 75 QUARTS (95 LITERS)
WE IGH T
NET 377 lb (171 kg)
SHIP 501 lb (227 kg)
CRATE 49" X 47" X 37" EST.
DIMENSIONS: (1245 x 1194 x 940mm)
EL ECT RIC AL 10 •10 ESi 10 •10 ESi /sk
VOLTAGE PHASE CYCLE/HZ AWG AMPS kW AMPS kW
at 208 1* 50/60 2 Wire plus ground 67.0 13.9 69.2 14.4
at 240 AWG 3 77.0 18.4 79.0 18.9
at 208 3 50/60 3 Wire plus ground 38.6/ph 13.9 40.0/ph 14.4
at 240 AWG 6 44.3/ph 18.4 45.5/ph 18.9
at 380 3 50/60 4 Wire plus ground 21.1/ph 13.9 22.0/ph 14.4
at 415 AWG 10 25.6/ph 18.4 26.3/ph 18.9
at 440 3* 50/60 3 Wire plus ground 20.0/ph 15.4 21.0/ph 15.9
at 480 AWG 8 22.0/ph 18.4 23.0/ph 18.9
* ELECTRICAL SERVICE CHARGE APPLIES
208-240
208-240
380-415
440-480
DI MEN SIO NS: H x W x D
EXTERIOR:
41-1/2" x 43-7/8" x 34-1/16" (1053mm x 1114mm x 865mm)
EXTERIOR WITH RETRACTABLE DOOR:
41-1/2" x 47-7/8" x 34-1/16" (1053mm x 1216mm x 865mm)
INTERIOR:
27" x 23-1/2" x 21-1/16" (685mm x 597mm x 535mm)
*ADDITIONAL WIRE SHELVES REQUIRED FOR MAXIMUM CAPACITY
IN STA LLAT ION RE QUI RE MEN TS
Oven must be installed level.
Hood installation is required.
Water supply shut-off valve and back-flow
preventer.
CL EAR ANC E R EQU IRE MEN TS
LEFT: 6" (152mm) PLUS SERVICE ACCESS: 18" (457mm) RECOMMENDED
20" (508mm) FROM HEAT PRODUCING EQUIPMENT
RIGHT
: 4" (102mm) TOP: 20" (508mm) FOR AIR MOVEMENT
BACK
: 4" (102mm) BOTTOM: 5-1/8" (130mm) FOR LEGS
COUNTER
-TOP INSTALLATIONS MUST MAINTAIN 4" (102mm) MINIMUM
CLEARANCE FROM COUNTER SURFACE
.
WATE R R EQU IRE MEN TS
TWO (2) COLD WATER INLETS - DRINKING QUALITY
ONE (1) TREATED WATER INLET: 3/4" NPT*
ONE (1) UNTREATED WATER INLET: 3/4" NPT*
LINE PRESSURE: 30 to 90 psi 2.8 to 6.2 bar
WATER DRAIN: 1-1/2"
CONNECTION WITH AIR GAP
* Can manifold off of one 3/4" line.
WATE R Q UAL ITY MI NIM UM STA NDA RDS
USING A WATER SUPPLY NOT MEETING ALTO-SHAAM'S
MINIMUM WATER QUALITY STANDARDS WILL VOID THIS
WARRANTY. It is the responsibility of the purchaser to ensure that
incoming water supply is compliant with the specifications listed
through adequate treatment measures. Installation of the
CombiGuard™ Water Filtration System is recommended, but this
system may not address all water quality issues present.
Contaminant Inlet Water Requirements
(untreated water)
Free Chlorine Less than 0.1 ppm (mg/L)
Hardness Less than 3 gpg (52 ppm)
Chloride Less than 30 ppm (mg/L)
pH 7.0 to 8.5
Alkalinity Less than 50 ppm (mg/L)
Silica Less than 12 ppm (mg/L)
Total Dissolved
Solids (tds) Less than 60 ppm