Grounding Instructions For Tools
With Three Prong Plugs
In the event of a malfunction or breakdown, grounding provides
a path of least resistance for electric current to reduce the risk of
electric shock.
Connection To A
Power Source
This machine must be grounded while in use to protect the
operator from electric shock.
Plug power cord into a 110-120V properly grounded type outlet
protected by a 15-amp dual element time delay fuse or circuit
breaker.
Not all outlets are properly grounded. If you are not sure that
your outlet, as pictured below, is properly grounded; have it
checked by a qualified electrician.
To avoid electric shock, do not touch the metal
prongs on the plug when installing or removing
the plug to or from the outlet.
Failure to properly ground this power tool can
cause electrocution or serious shock,
particularly when used near metal plumbing or other metal
objects. If shocked, your reaction could cause your hands to hit
the tool.
If power cord is worn, cut or damaged in any
way, have it replaced immediately to avoid
shock or fire hazard.
Your unit is for use on 120 volts; it has a plug that looks like the
one below.
This power tool is equipped with a 3-conductor cord and
grounding type plug, approved by Underwriters Laboratories
and the Canadian Standards Association. The ground conductor
has a green jacket and is attached to the tool housing at one end
and to the ground prong in the attachment plug at the other end.
This plug requires a mating 3-conductor grounded type outlet as
shown.
If the outlet you are planning to use for this power tool is of the
two-prong type, DO NOT REMOVE OR ALTER THE
GROUNDING PRONG IN ANY MANNER. Use an adapter as
shown and always connect the grounding lug to known ground.
Improper connection of the equipment-grounding conductor can
result in a risk of electric shock. If repair or replacement of the
electric cord or plug is necessary, do not connect the
equipment-grounding conductor to a live terminal.
Check with a qualified electrician or service personnel if the
grounding instructions are not completely understood, or if in
doubt as to whether the tool is properly grounded.
It is recommended that you have a qualified electrician replace
the TWO-prong outlet with a properly grounded THREE-prong
outlet.
An adapter as shown below is available for connecting plugs to
2-prong receptacles.
The green grounding lug extending from the
adapter must be connected to a permanent
ground such as a properly grounded outlet box.
NOTE: The adapter illustrated is for use only if you already have
a properly grounded 2-prong receptacle. Adapter is not allowed
in Canada by the Canadian Electrical Code.
The use of any extension cord will cause some loss of power. To
keep this to a minimum and to prevent overheating and motor
burn-out, use the table below to determine the minimum wire
size (A.W.G.) extension cord. Use only 3-wire extension cords
which have 3-prong grounding type plugs and 3-pole
receptacles which accept the tool’s plug.
Extension Cords
RECOMMENDED SIZES OF EXTENSION CORDS
DANGER
!
DANGER
!
WARNING
!
3-PRONG PLUG
GROUNDING PRONG
ALWAYS USE A
GROUNDED
OUTLET
3-PRONG
PLUG
SCREW
GROUNDING LUG
2-PRONG RECEPTACLE
ADAPTER
WARNING
!
MAKE SURE THIS
IS CONNECTED
TO A KNOWN
GROUND
Tool’s
Ampere
Rating
120 VOLT A.C. TOOLS
Cord Length in Feet
Cord Size in A.W.G.
240 VOLT A.C. TOOLS
Cord Length in Meters
Wire Sizes in mm
2
3-6
6-8
8-10
10-12
12-16
18 16 16 14 .75 .75 1.5 2.5
18 16 14 12 .75 1.0 2.5 4.0
18 16 14 12 .75 1.0 2.5 4.0
16 16 14 12 1.0 2.5 4.0
14 12
25 50 100 150 15 30 60 120
“SAVE THESE INSTRUCTIONS”