FPS/FPSE/FPD TECHNICAL TRAINING AND SERVICE WORKBOOK
FPSE 40 and 50 SERVICE AND OPERATION cant.
FPD 40 and 50 SERVICE AND OPERATION cant.
BLOWER RUNS CONSTANTLY (Calling for heat, pilot is lit, no main burner)
cont.
Trouble-
shooting cont.
RESULTS
If: then
the meter does not read continuity,
replace main valve.
the meter does read continuity,
check gas supply.